Send Us E-Mail

Weekly Special


Manufacturers
Products
Data Collection
Services
Feedback
Contact Us
Quick Links
Search

 

 

 

 

 

MSCS - Multiple System Console Solution
Multiple AS400 or iSeries System Consoles over TCP/IP

Full System Console Control for Multiple AS/400s or
Combination of AS/400?s and LPARs Over a TCP/IP LAN, WAN
or Virtual Private Network (VPN)

Overview

With the TwinNet SNA Gateway you can eliminate the problems of administering the System Console function in a multiple AS/400 environment.  The Multiple System Console Solution (MSCS) configuration will make System Console administration of multiple AS/400s as simple as opening a Window on a LAN attached PC.

The System Console is typically a "dumb" Twinax Display Station attached to Port 0 / Address 0 of your AS/400 or LPAR.  The System Console is the only terminal that can:

Image:  Screen Shot of 4 Sign On Screens

Click on image above for more screenshots.

  • Perform certain System Maintenance and Configuration Procedures (Restricted State)

  • Execute certain type of System Backups (SAVSYS)

  • Respond to certain types of "System Console Only" messages

 In the multiple system environment, this requires one terminal per AS/400.  It also requires that an operator be on site to respond to the message, or perform the particular procedure that can only be executed from the System Console.   When the operator is not on site, it usually requires a phone call or a page to a standby operations person who would need to either travel to the office or diagnose the problem over the phone.

TwinNet MSCS will allow these AS/400 or LPAR "System Console Functions" to be handled from anywhere on your LAN, WAN or VPN.   This also includes dial-in to a network attached Remote Access Server (RAS) such as a Shiva LanRover or a BOSaNOVA LanLynk.  This eliminates the necessity of the AS/400 operator to be at the normal location for the System Console - the computer room.

Click here for More Information on the TwinNet Multiple System Console Solution


Multiple System Console Solution (MSCS) Diagram

Diagram:  4 AS/400s connectted with Twinets to LAN

Click here for More Information on the TwinNet Multiple System Console Solution


Applications for MSCS with TwinNet
  • Control Multiple AS/400s  or LPARs from a single "System Console"

  • Control an AS/36 and AS/400 from the same System Console - Allows upgrading from one system to a new system to be more convenient.  You can also configure additional sessions from each system, up to seven (7) from each TwinNet SNA Gateway.

  • Allow a local network PC to be System Console for an AS/400 at a remote location - Improves system operation capabilities at other locations without the need for a system operator.

  • Allow System Consoles to be anywhere on your LAN/WAN/VPN

Some Features of MSCS with TwinNet
  • Flexible Twinax connection means increased productivity. The TwinNet solution uses a Twinax connection to the host IBM midrange system which means that it can support the IBM AS/400, System/36, Advanced Series/36 and Twinax Remote Controllers. Since TwinNet provides a single point of contact to the midrange host, there is less configuration and operating overhead, providing better overall host performance.

  • Simple, intuitive installation and configuration. On the PC side, a single protocol can be used for both LAN and host PCs, and since TwinNet is a native Twinax gateway, it does not require the overhead and configuration complexities of an APPC router.  And the TwinNet Gold Client software installs quickly and easily, using industry-standard LAN interfaces.


TwinNet
Diagram: TwiNet Installation example The picture on the left shows a standard TwinNet installation. The IBM Host can be any S/3X, AS/400 or Remote Control Unit with a Twinax attachment installed. TwinNet can be installed either close to the Host or close to the Clients, using the existing Twinax or UTP cabling very good for long distance connection (up to 5000 feet).

 

Information Request Form - Click Here

Download the TwinNet Data Sheet

For more information on TwinNet, contact us at 800-597-2525
or e-mail us at info@twindata.com

 

 


|
Home |  | Products |  | Manufacturers |  | Weekly Special |  | Company & Contact Information |  | Feedback |
| Quick Links | | Site Map |  |
Warranty & Support |  | Privacy Policy |  | Shopping |  | Refund Policy |

 


PLEASE CLICK HERE to send us questions or comments about this web site.
Telephone:  USA 1-800-597-2525 / International 1-908-855-8100 / FAX 1-908-855-8101
Copyright©
2026 Twin Data Corporation